DNA and Primer Sent Separately
SeqWright does not require premixing of DNA and primer for submissions. The main benefits of not premixing are:
|
Customers may request additional reactions to be performed on a particular DNA template without having to ship more sample |
|
SeqWright can troubleshoot projects, such as adjusting DNA-primer concentration or choosing alternate primer sites in the event of poor sequencing quality following first round attempts |
|
Template purification or amplification may be performed if necessary |
For submitting DNA and primer separately, please refer to the following table:
Template |
Concentration |
Volume / RXN |
Plasmid |
50 ng/µL |
10µL |
PCR < 500 |
20-30 ng/µL |
10µL |
PCR > 500 |
30-50 ng/µL |
10µL |
Primer |
5µM |
10µL |