Clinical Trial Services
FDA Level Sequencing
FDA Level QPCR
FDA Level Microarray
FDA Level Microbial ID
GeneticStabilityTesting
Biorepository
Biomarker Discovery
 
Research Services
Next Gen DNA Sequencing
DNA Sequencing
Molecular Genetics and Genomics
Microarray
 
Personal Genomic Profiling Service
Developments in Gene Testing
About Genomics
Why SeqWright
Privacy Protection
How to Order
My GPS Results
 

 

 

Shipping Information

Shipping Address
SeqWright, Inc.
Attn: New Order Request
2575 West Bellfort
Suite 2001
Houston, TX 77054

Sample Submission Requirements
For the best results, please follow these requirements:

QC Your DNA
The #1 reason for poor sequencing results is that researchers do not take the time to QC their samples, whether by OD or agarose gel. Simply performing a mini-prep is not sufficient as it does not guarantee the appropriate concentration and yield for sequencing. Please verify your sample quality and amounts before submitting.

DNA and Primer Sent Separately

SeqWright does not require premixing of DNA and primer for submissions. The main benefits of not premixing are:
  • Customers may request additional reactions to be performed on a particular DNA template without having to ship more sample
  • SeqWright can troubleshoot projects, such as adjusting DNA-primer concentration or choosing alternate primer sites in the event of poor sequencing quality following first round attempts
  • Template purification or amplification may be performed if necessary

For submitting DNA and primer separately, please refer to the following table:

Template
Concentration
Volume / RXN
Plasmid
50 ng/µL
10µL
PCR < 500
20-30 ng/µL
10µL
PCR > 500
30-50 ng/µL
10µL
Primer
5µM
10µL

PLEASE NOTE: Typically we request more DNA than we need in order to have a sufficient quantity for any repeats that we may need to perform. In addition, a researcher may get different sample concentration values depending on his/her quantitation method.

DNA & Primer Combined
For sending combined samples, please refer to the following chart:

DNA Type

Size

DNA Conc. in H2O

DNA Volume

Total Amount

Primer Conc.

Primer Vol.

Plasmid

<6kb

40-60 ng/µl

8 µl

~500 ng

2 pmole/µl

4 µl

Plasmid

6-10kb

60-80 ng/µl

8 µl

~600 ng

2 pmole/µl

4 µl

Plasmid

>10kb

80-100 ng/µl

8 µl

~800 ng

2 pmole/µl

4 µl

PCR Product

<1kb

5-15 ng/µl

8 µl

~80 ng

2 pmole/µl

4 µl

PCR Product

1-2kb

~20 ng/µl

8 µl

~150 ng

2 pmole/µl

4 µl

Standard Single-Tube DNA Sequencing (Purified Plasmids & PCR Products)
Please submit DNA and primers at volumes/concentrations according to the chart above. We do not accept PCR strip tubes for our single-tube service; only standard 1.5 mL bullet tubes or 2 mL screw cap tubes. Each tube must be clearly labeled with the sample's identity. We recommend putting your tubes in a larger 50 mL tube for added protection during shipment. DNA should be shipped overnight (next day delivery) at room temperature.

Acceptable Container Types

Shipping Conditions

Comments

1.5 mL Bullet Tube; 2mL Screw Cap Tubes

Overnight Mail @ Room Temperature

No PCR Strip Tubes

96-Well Plate DNA Sequencing (Purified Plasmids & PCR Products)
Please submit DNA and primers at volumes/concentrations according to the chart above. Plates must be arrayed A1-H1, A2-H2...etc. as follows:

It is very important that plates are sealed and shipped FROZEN on dry ice.

Acceptable Container Types

Shipping Conditions

Comments

96-Well Semi-Skirted PCR Plates; 384-Well PCR Plates

Overnight Mail; Cooler; Dry Ice

No PCR Strip Tubes

qPCR Sample Requirements:

Quantity
Solution
Concentration
2-3 ug DNA/RNA
Water or TE Buffer
250 ng/ul


Other Common Sample Types:

Template Type

Shipping Conditions

Glycerol Stocks

Frozen; Dry Ice

Colonies/Agar Plates

Room Temperature; Petri Dish Sized Plates Only

Libraries (Transformation & Ligation Mixtures)

Frozen; Dry Ice

RNA

Frozen; Dry Ice